Accuster Auto-microscope model: ATMS51 is an automatic microscope developed for the acquisition of high resolution images in bright field observation.

The motorized XY sample stage helps the user to scan a particular sample area automatically and the autofocusing system will find the best focused image in each frame before saving it to the Drive for further analysis.

Transmitted warm white LED illumination along with high quality Plan achromatic microscope objective provides uniform illumination of the entire field of view.
The system is equipped with 8MP camera for the fast acquisition of the images and a 40X, 100x Plan objective for high resolution images.

Accuster Auto microscope (ATMS51) uses a smartphone for capturing the images. It enables the pathologist to report the result remotely within a short span of time which reduces the treatment delay.
The Auto-microscope has many capabilities, such as
Auto focusing,
Auto scanning,
Auto Image capturing

Our Auto microscope is controlled using Bluetooth. All these features are included in the inbuilt android application of the Auto-microscope
(Microscope).

Automated microscopy minimizes user interference for more productive and effective microscopy applications in life sciences.

ACCUSTER AUTO-MICROSCOPE

FEATURES OF AUTO-MICROSCOPE

  • Inbuilt
  • Auto Focusing
  • Image Capturing
  • Auto Scanning
  • Bluetooth Enabled
  • Low-cost Automated Solution For Pathology.
  • Can Save Smear Images
  • Less Power Consumption -48 W
  • Cloud Storage Of Digitized Images
  • Inbuilt Android Application Support ( Microscope)
  • Adaptable To Multiple Smart Phone

Our Automicroscope ATMS51 offers a convenient and transparent solution along with an innovative design that has multiple applications in various hospitals, research centers, pathology labs at affordable market price.

center

SPECIFICATIONS

Observation methodBright field
Illumination sourceHigh Bright warm White LED (Intensity Adjustable)
Microscope objectivePlan Achromatic (4x 10x 40 x and 100x)
FocusingAuto focusing
Image acquisition120 images / 20 Minutes
SoftwareMICROSCOPE ( Patient’s registration, Sharing of images, etc. )
Camera DetailsSensor: Color, 8Mp, Picture format : JPEG
Operating modeContinuous output
XY sample stageMotorized
Travel20mm x 20mm
DriveStepper Motor (COMMAND MOVES IN STEPS 3.75 (STEP ANGLE)
Eyepiece LensWidefield CWF 15X/ F.O.V 18mm (paired), high eyepoint.
 

 

Power Supply

Plug-in external SMPS power supply input 100/240vac, 50/60Hz; Output;12Vdc4A. Plugs into DC socket fitted into the microscope rear mainframe.
Standard Main FrameC-arm main frame die-casted aluminum frame with built-in LED illuminator base ( small foot print) painted with white textured finish, antifungal PU paint.
Built-in White Led IlluminationHigh Intensity pre-centered 3 watts LED, variable light intensity control with ON/OFF switch, Easy LED change. LED technology provides warm white even Illumination, energy-efficient light for upto 50,000 hours.
Mechanical Stage RectangularPrecision ball bearing type, traverse 76mm (X) and 50mm ( Y ), vernier reading 0.1mm, low positioned co-axials Knobs, soft feel,and fluid movement. XY motorized axis with precise stepper motors.

Accuster AutoMicroscope VS. Automated cell counter

S.no.

 Auto Microscope

Blood Cell counter

1 InexpensiveExpensive
2 Movable in fieldStatic
3 Cost per test is very lowCost per test is high
4 Maintenance freeMaintenance required, extra Investment
5 Able to do more analysis like Urine Microscopy, Malaria parasite, Sickle cell, Absolute eosinophil count etcOnly Complete blood count will be performed
6 Calibration not requiredCalibration required 
7 Less power ConsumptionHigh power Consumption
8 Grounding or Online UPS not requiredGrounding or Online UPS required
9 Having proper records of AccuracyRecords will be available in graphical form only.
10 Can work in any conditionsAmbient temperature 25°C required
11 DurableDelicate Technology (More prone to damage)

 

Accuster Auto Microscope vs Manual Microscope

S.no.

   Accuster Auto Microscope

Manual AutoMicroscope

1 Auto focusingFocus needs to be adjusted by pathologists
2 Inexperienced user can obtain sample
images easier and faster
High skilled manpower required
3 Auto Image capturing ,sample images are analyzed directly on an electronic monitor display, less time consumingSlides are examined through eyepieces , hence more time consuming
4 Bluetooth EnabledManually controlled
5 Have Patient Registration software.No software support hence takes a lot of time for data maintenance and storage
6 Sample images can be shared through cloud hence Instant reportingSample data cannot be shared from one location to another through online connectivity 
7 Auto scanning, helps in Region Identification of the sampleSlide needs to be adjusted for region Identification
8 Image capturing, Works as a Evidence, No data manipulationReports can be manipulated since no evidences/Images of the sample
9 Having proper records of AccuracyRecords will be available in graphical form only.
10 Can work in any conditionsAmbient temperature 25°C required
11 Comes with supplementary Devices, Stainer and Smear Device (ACCURAPID STAINER AND ACCU SMEAR DEVICE)Not featured with Stainer and Smear Devices.

 